Still deciding? Get samples of $ !
Order Sample
|
| Customization: | Available |
|---|---|
| After-sales Service: | Provide Warranty Service |
| Warranty: | 1year |
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
| Payment Methods: |
|
|---|---|
| Support payments in USD |
| Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
|---|
| Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
|---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency




Features
1,Removable and interchangeable measuring element,easy to maintain
2,Dry type register and vacuum-sealed to prevent water condensation inside and frost
resistance
3,Magnetic transmission keeps the register completely separate from water
4,Large flow capacity and small pressure lose
5,Epoxy Coated Cast lron body with Metal Protective Lid
Dimensions
| Type | Nominal Size (mm) | Size (inch) | Length | Width | Height | Outside diameter D | Bolt circle Dia D1 | Connecting Bolt (n-Md) |
| LXLC-50 | 50 | 2'' | 200 | 170 | 270 | 165 | 125 | 4-M16 |
| LXLC-65 | 65 | 2-1/2'' | 200 | 175 | 270 | 185 | 145 | 4-M16 |
| LXLC-80 | 80 | 3'' | 230 | 200 | 285 | 200 | 160 | 8-M16 |
| LXLC-100 | 100 | 4'' | 250 | 225 | 290 | 220 | 180 | 8-M16 |
| LXLC-125 | 125 | 5'' | 250 | 250 | 300 | 250 | 210 | 8-M16 |
| LXLC-150 | 150 | 6'' | 300 | 290 | 350 | 285 | 240 | 8-M20 |
| LXLC-200 | 200 | 8'' | 360 | 340 | 385 | 340 | 295 | 8-M20 |
| LXLC-250 | 250 | 10'' | 450 | 410 | 450 | 395 | 350 | 12-M20 |
| LXLC-300 | 300 | 12'' | 500 | 460 | 500 | 445 | 400 | 12-M20 |
Technical Data
| DN(mm) | 65 | 80 | 100 | 125 | 150 | 200 | 250 | 300 | |
| Q4(m³/h) | 50 | 78.75 | 125 | 200 | 312.5 | 500 | 787.5 | 1250 | |
| Q3(m³/h) | 40 | 63 | 100 | 160 | 250 | 400 | 630 | 1000 | |
| R=80 | Q2(m³/h) | 0.8 | 1.26 | 2 | 3.2 | 5 | 8 | 12.6 | 7.5 |
| Q1(m³/h) | 0.5 | 0.7875 | 1.25 | 2 | 3.125 | 5 | 7.875 | 12.5 | |
| Max.Reading(m3) | 99999 | 99999 | 99999 | 99999 | 99999 | 99999 | 99999 | 99999 | |
| Min.Reading(Liter) | 0.0001 | 0.0001 | 0.0001 | 0.0001 | 0.0001 | 0.0001 | 0.0001 | 0.0001 | |
| Max.Pressure(Bar) | 16 | 16 | 16 | 16 | 16 | 16 | 16 | 16 | |
| Pressure Loss | △P63 | ||||||||
| Class of measurement |
B | ||||||||
| Water pressure | 1.0Mpa/1.6Mpa | ||||||||
| Water temperature | 01°~40ºC(01'ºC~90'ºC for hot water meter) | ||||||||
| Maximum Permissible Error |
(1)in the lower zone from qmin inclusive up to but excluding qt is+5% (2)in the upper zone from qt inclusive up to and including qs is±2% (±3%%for hot water meter) |
||||||||
| Water pressure | ≤1.0Mpa(1.6MPa on request) | ||||||||
| Standard | ISO9001/ISO4064/ISO17025/CE | ||||||||
| Connection | Flange | ||||||||